Hotel Furniture Fire Safety Standards: BS 5852, TB 117-2013 and IMO MED Explained
Hotel furniture has to meet the fire standard written into the project specification, and that standard depends on where the hotel is and what the operator requires. In the UK and many international brand standards, upholstered seating is commonly specified to BS 5852 with the Crib 5 ignition source. Projects that follow US practice often reference California TB 117-2013. Furniture for ships and some marine projects falls under IMO rules and the EU Marine Equipment Directive (MED), and Gulf projects add the local civil-defence requirements. The right approach is to fix the standard before samples are made, because it changes foams, fabrics, interliners and documentation.
This guide explains what each reference covers, where it usually applies, and how a manufacturer should handle compliance across a full hotel furniture package.
Why fire performance has to be decided at the specification stage
Fire performance is not a finish you add at the end. It is built into the layers of an upholstered piece: the foam grade, the fabric and its treatment, the interliner between them, the filling, the thread and even the way the cover is fitted. Change one layer and the result of a test can change.
That is why experienced FF&E teams put the fire requirement in the first version of the specification, next to dimensions and materials. When it arrives late, the usual consequences are:
fabrics chosen by the designer that cannot pass without a barrier interliner or a back-coating,
foam that has to be replaced after prototypes are already approved,
mock-up rooms rebuilt because the compliant fabric looks or feels different,
test reports that refer to a different fabric colourway or composition than the one delivered.


The main fire references and where they apply
BS 5852 and the Crib 5 ignition source
BS 5852 is a British standard for assessing how upholstered seating resists ignition from different sources, from a smouldering cigarette and a small match-equivalent flame up to wooden cribs of increasing size. Crib 5 is the wooden crib source that is widely written into contract and hospitality specifications, because public spaces carry a higher risk than a private home.
In practice, a Crib 5 requirement means the specific combination of cover fabric, interliner and filling must be tested together. A fabric certificate on its own does not prove that the finished chair complies. When a project specifies BS 5852 Crib 5, ask for:
the test report for the actual composite (fabric plus foam plus interliner),
confirmation that the delivered fabric matches the tested one in composition and weight,
the treatment method used, if the fabric was treated after weaving,
a schedule that links every upholstered item code to its tested composite.
CAL TB 117-2013 for projects following US practice
California Technical Bulletin 117-2013 focuses on smoulder resistance of the materials used in upholstered furniture, tested with a cigarette as the ignition source. It replaced an earlier version that relied on an open-flame test of the foam. Many hotel projects in the Americas, and some international projects that follow US brand standards, reference TB 117-2013 for guestroom and public-area seating.
The key point for buyers is that TB 117-2013 and BS 5852 Crib 5 are different tests with different aims. Passing one does not mean passing the other. If a brand standard lists both, or if the hotel will be audited against both, the composite has to be tested for both.
IMO and MED for ships, yachts and marine-grade interiors
Furniture for passenger ships and yachts is governed by the IMO Fire Test Procedures Code, and for vessels under EU flags the products are certified under the Marine Equipment Directive, which uses the wheel mark. These rules cover upholstered furniture, bedding components and some surface materials. They are stricter in documentation than most land-based hotel rules, because each product type needs its own certified route.
If a resort includes a yacht, a floating restaurant or a marine-grade lounge, treat that part of the package as a separate compliance stream with its own approved materials list.
Gulf civil-defence requirements
Hotels in Saudi Arabia, the UAE, Qatar and other Gulf states must satisfy the local civil-defence authority. The applicable requirement depends on the emirate or city, the building type and the consultant's specification. Some projects reference British standards, others add local approvals for specific materials. The safe route is to confirm the requirement in writing with the project consultant before sampling, and to keep certificates in a format the local authority accepts.

How compliance is handled in a turnkey FF&E programme
At Sagist Group, fire performance is set at the value engineering stage, before CAD/BIM shop drawings are issued, and it travels with each item through the six stages we run under one contract: value engineering, shop drawings, 1:1 prototypes and mock-up rooms, manufacturing, logistics and customs, and installation by our own crews. The fire references we work with are BS 5852 Crib 5, CAL TB 117-2013, IMO MED and Gulf civil-defence requirements, always according to the project specification.
Because upholstery, joinery, metal, stone and lacquer are made in-house across five factories in Istanbul, the same team that selects the foam also builds the frame and fits the cover. That keeps the tested composite and the delivered product the same. You can see the range of hotel pieces we produce on our hotel furniture page.

Fire safety checklist for hotel furniture buyers
Use this checklist before you approve samples:
Write the fire standard for each furniture category into the specification (guestroom, public areas, restaurant, outdoor, marine).
Confirm the standard with the operator's brand standards and the local authority.
Ask the manufacturer for tested composites, not only fabric certificates.
Check that designer-selected fabrics can pass, or agree an interliner or a compliant alternative early.
Link every upholstered item code to a test report in the FF&E schedule.
Keep samples of the approved composite, labelled and sealed, for comparison on delivery.
Include the certificates in the handover file in the language the authority requires.

Frequently asked questions
Which fire standard applies to hotel furniture?
The one written into the project specification. In UK-influenced and many international projects it is often BS 5852 Crib 5 for upholstered seating; projects following US practice often use CAL TB 117-2013; ships use IMO and MED; Gulf projects add civil-defence rules.
Is a fire-retardant fabric certificate enough?
Usually not. Standards such as BS 5852 test the fabric, interliner and filling together, so the report should cover the full composite used in the delivered piece.
Are BS 5852 Crib 5 and TB 117-2013 the same?
No. They use different ignition sources and test methods. A piece that passes one has not automatically passed the other.
Does fire treatment change how a fabric looks or feels?
It can. Back-coatings and some treatments affect drape and handle, which is why compliant fabrics should be approved in the mock-up room before production.
When should fire requirements be agreed?
At the start, in the specification and value engineering stage, before prototypes. Late changes affect foams, fabrics and the programme.
Does outdoor and restaurant furniture need the same rating?
Not always. Requirements differ by area and authority, so list them per category. Our restaurant furniture and outdoor pieces follow the rating set for each area.

Plan fire compliance with your manufacturer
If you are preparing an FF&E specification and want the fire references set correctly from the first sample, send us the drawings and brand standards through our contact page or on WhatsApp. We will map each furniture category to its standard and show how it affects materials and the programme. You can also browse our hotel furniture projects.
#sagistgroup #hotelfurniture #firesafety #hotelffe #contractfurniture #upholstery #hoteldesign #madeinturkiye
Written by: Metin Durmaz (Architect & CEO)
Last updated: 28 November 2026
Written by: Metin Durmaz (Architect & CEO) · Reviewed by: Ayça Öztürk (Lead Architect & Director of Space)




Comments